5 Reddit comments about Camco Blow Out Plug With Brass Quick Connect-Aids In Removal of Water From Water Lines (36143):

u/Codebender · 5 pointsr/Skookum

> Obviously the run current is way out of spec, but I don't know what would cause this.

Two things come to mind:

1. If the water supply line is somehow becoming intermittently blocked, that could cause overloading. Not sure how that would happen, though, I'd say a problem at the pump is more likely.

2. Your might be over-drawing. Your pump expects to be submerged and water-cooled, if the water draws down too far it spins free, you get no water, and it overheats. This is often accompanied by muddy water, but not necessarily. Most townships have public well logs, so you might check if you have the shallowest well in the area, and ask around if anyone at a similar depth has had issues.

If you have a bypass valve or slip joint at the pump head, open it and turn on the pump to see if there's any difference without the tank and lines in play. The more you can isolate the problem, the better.

I might also try powering everything down and "snaking" with 65 feet of wire just to see if I hit anything before calling for the pump to be pulled.

I'm sure this isn't officially recommended, but personally I would also try using an air/water fitting, something like this, shut everything down-stream, and blow the pump line out backwards, regulated to no more than 55 psi. If that helped, it would mean you've got some crap pulled into your pump and it's just going to happen again, but the pump itself might be ok.

Just pulling the pump and putting it back will probably cost a few hundred dollars in labor and new pipe. A ten-year warranty is not uncommon for a pump like that, though, so you might get a break if you have to replace it and can find the info. Otherwise, expect maybe $3-500 for a new ~10gpm pump.

u/AffableJoker · 4 pointsr/RVLiving

I agree with troubleshooting, a lot of times sediment from the water heater will get kicked up and clog a line.

The fact that you have cold pressure but not hot eliminates the shower head and shower hose as culprits. That leaves the hot water line itself and the hot side of the faucet.

The first thing I would do is switch the hot and cold on the back of the faucet and see if you get full pressure from the hot line when it's connected to the cold side of the faucet, that would indicate that the problem is in the faucet itself.

If that doesn't work I would follow the hot line as far as you can to be sure it's not kinked anywhere. If it's not I would drain all the water from the RV through the low points, remove the line from the shower faucet side, bypass the water heater, close the low points, and blow the line out through your city water with compressed air with something like this.

Edit: have someone with a bucket at the detached shower line, it'll make a huge mess if it's not directed into the shower.

u/senorpoop · 2 pointsr/GoRVing

Do yourself a favor and spend seven bucks and do it the right way. It will even save you a bunch of time.

Buy this product:

https://www.amazon.com/Camco-Brass-Connect-Aids-Removal-36143/dp/B002XL2IEA

Drain your tanks. Leave the drains open, open all of your faucets, hook this up and run ~40-50 psi compressed air through your lines for about 5 minutes. Disconnect, leave the faucets and drains open, pour a little antifreeze down each drain so it's in the P traps, and you're done. There is absolutely no need to go so overboard, and you're wasting a bunch of time.

u/thedudeintx82 · 2 pointsr/GoRVing

https://www.amazon.com/Camco-Brass-Connect-Aids-Removal-36143/dp/B002XL2IEA

This is the adapter I have. It hooks up to the quick connect hose I have on my 5 gallon air compressor. I don’t know if a plug in will work with it, just a heads up.

Also’ make sure you blow out the toilet. I have a friend that didn’t once and it cracked the valve.

u/grizzlyboxers · 1 pointr/GoRVing

You'd connect a gadget like in the link below to your city water connection. No it won't clear your freshwater tank as that will have its own drain.

Camco Blow Out Plug With Brass Quick Connect-Aids In Removal of Water From Water Lines (36143) https://www.amazon.com/dp/B002XL2IEA/ref=cm_sw_r_cp_apa_i_DTbYDb4CT1YXS